[Dec 15, 2024] PassCollection D-PE-OE-23 Exam Practice Test Questions (Updated 325 Questions) [Q147-Q165]

Share

[Dec 15, 2024] PassCollection D-PE-OE-23 Exam Practice Test Questions (Updated 325 Questions)

Pass EMC D-PE-OE-23 Exam Info and Free Practice Test

NEW QUESTION # 147
A technician must create a RAID array that uses striping with double parity.
Which RAID level must be used?

  • A. RAID 6
  • B. RAID 50
  • C. RAID 10
  • D. RAID 5

Answer: A


NEW QUESTION # 148
A system administrator is trying to connect with a mobile device to a Dell PowerEdge 16G server using Quick Sync 2. They failed to make a connection.
What is the reason for the failure?

  • A. NFC is disabled on the mobile device.
  • B. Bluetooth is disabled on the mobile device.
  • C. The mobile device is using iOS.
  • D. There is no iDRAC IP address configured.

Answer: B


NEW QUESTION # 149
A server in an unattended remote site powers down unexpectedly. The technician assigned to the customer cannot arrive on-site until tomorrow. The customer needs the server back up and running today.
What should the technician do?

  • A. Access the iDRAC interface and power the server on remotely
  • B. Use the RDP utility and power the server on remotely
  • C. Log into the Lifecycle Controller and remotely power on the server
  • D. Issue a Power Supply Unit reseat command using a remote CLI

Answer: A


NEW QUESTION # 150
A technician has just upgraded memory modules in a server. When the technician loads the iDRAC, the new memory is NOT listed. The OS reports all memory.
Where should the technician troubleshoot this issue?

  • A. Boot to F2, select System BIOS > Integrated Devices. If enabled, disable "Collect System Inventory on Restart". Restart the system, then return to the menu and enable it again.
  • B. Boot to F2, select iDRAC Settings > Lifecycle Controller. If enabled, disable "Collect System Inventory on Restart". Restart the system, then return to the menu and enable it again.
  • C. Boot to F2, select System BIOS > Memory Settings, and enable System Memory Testing
  • D. Boot to F2, select iDRAC Settings > Memory Settings, and make sure Memory Operation Mode is Mirrored.

Answer: B


NEW QUESTION # 151
A system administrator is trying to connect a 128 GB flash drive to an iDRAC Direct USB port on a Dell PowerEdge R660 server running Red Hat Enterprise Linux 8. They failed to discover the drive from the operating system.
What is the reason for the failure?

  • A. The port only supports devices under 64 GB.
  • B. The flash drive is formatted as FAT32.
  • C. The port is set to iDRAC Direct only.
  • D. Flash drives are not supported.

Answer: C


NEW QUESTION # 152
A technician tries to power on a server but nothing happens when they press the power button. The status LEDs on both PSUs are green. The technician is able to connect to the iDRAC to review the System Event Logs and discovers that PSU2 has failed.

  • A. Cycle the AC power
    Test one PSU at a time
  • B. Reboot the server
    Test one PSU at a time
  • C. Cycle the AC power
    Reset the NVRAM
  • D. Reboot the server
    Reset the NVRAM

Answer: A


NEW QUESTION # 153
You are creating a new RAID 5 storage pool on a Dell EMC PowerEdge server based on 30 x 1TB drives.
Which PERC model best supports this configuration?

  • A. H740P
  • B. H740T
  • C. S140
  • D. H330

Answer: C


NEW QUESTION # 154
A technician is configuring the server to boot to the Internal Dual SD Module.
Which BIOS boot option should the technician select?

  • A. Hard Drive C
  • B. DVD-ROM
  • C. vFlash Media
  • D. Integrated NIC

Answer: C


NEW QUESTION # 155
A company is implementing Superna Eyeglass to automate and orchestrate SyncIQ failover and failback.
What is one of the requirements when implementing Superna Eyeglass for a Dell EMC Isilon cluster?

  • A. Dedicated subnet must exist
  • B. System Access zone must be used
  • C. Dedicated IP pool must exist
  • D. Administrator account must be used

Answer: A


NEW QUESTION # 156
What type of fans are installed in servers with NVMe storage and GPU configurations?

  • A. HPR
  • B. LFM
  • C. STD
  • D. VHP

Answer: D


NEW QUESTION # 157
Case Study 4
A company is experiencing a noticeable decrease in performance when accessing data on their Dell EMC Isilon cluster. The cluster hosts Microsoft Windows home directories and general purpose file shares. In addition, a file pool policy moves data that has not been modified in six months to an achieve tier.
The administrator wants your assistance in understanding the reason for the slow data access. The number of users accessing the cluster has not changed. The administrator has shared the following baseline metrics. The outputs were captured from a performance- acceptable time frame.
Trace route shows:
- 3 hops between clients and the cluster
- Average latency is 3 ms
Iperf shows:
- 940 Mb/s average bandwidth
- 005 ms average jitter
Netstat on the local network shows:
- 05% average re-transmission rate
Hostcache list:
- 20 ms average roundtrip time across all clients
The administrator shows you the details of the hostcahce.list output. The output indicates that the top clients on the list have an average of 242 ms round trip time.
Based on the output, what information should be provided to the administrator?

  • A. Only the aggregate of all average round trip times will indicate an issue.
  • B. An increase in the average round trip time indicates a network problem.
  • C. Recalculate and re-populate round trip times by using isi_cbind clear command.
  • D. An average round trip time less than 300 ms is in the acceptable range.

Answer: A


NEW QUESTION # 158
A technician is deploying a new server in a datacenter and must install Microsoft Windows Server
2016. They have placed the OS media in the DVD attached to the server.
What does the technician need to do to install the OS using the Lifecycle Controller?

  • A. Configure storage
  • B. Restore server profile
  • C. Configure Lifecycle Controller network settings
  • D. Disable iDRAC virtual media

Answer: A


NEW QUESTION # 159
A technician needs to update the iDRAC license on a PowerEdge R740 server from Express to Enterprise.
The server has the following components:
- 2x CPUs
- 384 GB RAM
- 6x 1 TB drives
- 1x PSU
The server is powered down but connected to active AC. The user wants it to stay powered down and not connect to any networks. No errors are presently displayed.
How can the technician upgrade the license?

  • A. The license cannot be upgraded because the user will not allow the server to be powered on
  • B. Power on the server then connect to the iDRAC and upgrade iDRAC license before powering the server down
  • C. The license cannot be upgraded on a single PSU system
  • D. Connect to the iDRAC GUI and upgrade the iDRAC license while the server is powered down.

Answer: D


NEW QUESTION # 160
A technician is ready to deploy a Dell EMC PowerEdge server. If a critical part on the system board fails, they must be able to replace the system board, reconfigure components, and update the firmware revisions in the shortest possible time.
How should the technician meet this requirement?

  • A. Use the iDRAC GUI to back up the Server Profile
  • B. Use the iDRAC Rollback feature to restore the firmware revisions
  • C. Back up component configurations using iSM
  • D. Back up the profile using the System Profile Settings feature

Answer: A


NEW QUESTION # 161
What type of screwdriver is required to remove the processor heat sink module?

  • A. Torque
  • B. Hex
  • C. Phillips
  • D. Torx

Answer: D


NEW QUESTION # 162
A server has six memory modules attached to each CPU Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.
What should the technician install/configure?

  • A. Six additional memory modules matching the original
    Switch on Single Rank Spare Mode
  • B. No additional memory
    Switch to memory Mirroring
  • C. No additional memory
    Switch on Single Rank Spare Mode
  • D. Six additional memory modules matching the original Switch to Memory Mirroring

Answer: D


NEW QUESTION # 163
A company's servers were ordered with iDRAC Enterprise with vFlash. The server profile was backed up after the first boot. Changes have been made to the server BIOS settings and firmware versions, which have resulted in many performance issues.
What is the most efficient way for the technician to address the performance issues?

  • A. Restore system profile using the iDRAC or Lifecycle Controller
  • B. Upload the approved corporate firmware versions from the file share
  • C. Reboot the server to F10 and perform System Repurpose/Retire
  • D. Run the racadm racresetcfg command to reset all server settings

Answer: A


NEW QUESTION # 164
What are two requirements for using the iDRACS Quick Sync feature? (Choose two.)

  • A. Bluetooth connectivity
  • B. Type A/A USB cable
  • C. NFC enabled mobile device
  • D. OpenManage Mobile app

Answer: C,D


NEW QUESTION # 165
......

Pass Your EMC Exam with D-PE-OE-23 Exam Dumps: https://www.passcollection.com/D-PE-OE-23_real-exams.html

D-PE-OE-23 Exam Dumps PDF Updated Dump from PassCollection Guaranteed Success: https://drive.google.com/open?id=1BE3Bc512fZE9Sn13hLOKrwLxCx_5NTvz